North America Water Supply System Summary
Water tower supply
Towerless water supply
Water tower mixing supply
Water Tower Supply
Water tower summary
Millions investment on the land, construction
Water treatment cost
High risk of water pollution: snake, mouse,
bug and small animal
Keep the temperature in winter to prevent
freezing
Lon-Term maintenance
Insufficient pressure, unstable water supply
Clean water tower and scale regularly
No friendly environment and landscape
Customer amount and types limited
Water tower construction
Waste time, big investment, and risk
Pest
contamination
Water tower maintenance:
Waste money, waste time
Why towerless water supply summary better
Low investment and friendly environment and
landscape.
Direct water supply, stable water pressure,
regardless of water consumption.
Power saving and low noise.
Fully automation control and monitoring, remote
control, low operating costs, and low maintenance,
reliable operation.
Automatic switching of backup power in case of
power failure and emergency, without interruption
of water.
Bypass design, low-cost backup power supply,
reduce the risk of water outage.
All metal closed-loop design, isolates drinking water
from pollution, small animals, and bugs.
Continued
PID negative feedback closed-loop control system
can arbitrarily set the water supply pressure and
expand the number and variety of users in a wide
range.
Preset sleep state at night, automatically shut
down and enter sleep state when not using water,
saving energy consumption. Automatically wake
up and enter the working state when the water
pressure drops.
Comprehensive water pump protection: water
shortage, short circuit, overloads, heat, jams,
phase loss or unbalance.
Integrated structure, highly intelligent integrated
design. The size of control panel is very small and
occupies a small area, which can be flexibly placed.
Closed-Loop Design Water Supply System:
Isolates drinking water from pollution, small animals, and bugs.
PID Negative Feedback Closed-Loop Control System
Water supply monitoring system
Water tower protection system
Water tower mixing supply
Upgraded existing water tower
1. Existing water tower as backup
2. Upgrade to towerless water supply
Reduce maintenance cost
Reduce water pollution
Stable pressure and water supply
Realize automatic control, monitoring and
remote control
Extending the number and variety of users
24/7 service
Water Tower
Millions investment on the land, and
construction >>1 million
No friendly environment and landscape
Insufficient pressure, unstable water supply
Water treatment cost
High risk of water pollution: snake,
mouse, bug and small animal
Keep the temperature in winter to
prevent freezing
Long-term maintenance
Clean water tower and scale regularly
Customer amount and types limited
Towerless Water
low investment<<1 million
Friendly environment and landscape.
Direct water supply, stable water pressure,
regardless of water consumption.
No water treatment cost. All metal closed-loop
design, isolates drinking water from pollution, small
animals, and bugs.
Fully automation control and monitoring, remote
control, low operating costs, and low maintenance,
reliable operation.
Automatic switching of backup power in case of
power failure and emergency, without interruption
of water.
Bypass design, low-cost backup power supply,
reduce the risk of water outage.
Power saving and low noise.
VS
Water Tower Design-Modular water storage tanks
Water Tower Design-Modular VFD, Pumps and Valves
Modular VFD Modular Pumps & Valves
Pumps & Valves
Inside
connect
Water Tower Design-Remote Wireless Controller
Remote Wireless Controller installation Diagram
Automatic wireless water level controller
The Diagram of Automatic Remote
Wireless Water Level Controller City water
Well water
The Diagram of Automatic Remote Wireless Water Level Controller
Schematic diagram of the controller
Water shortage protection
Sho
r
Sh
or Sh
or
Pr WS
Al Pw
Water
level
switch
E-Push
Towerless water supply Summary
Continued***
A normal operating pressure of 35 pounds per square inch (psi) throughout the system. A minimum pressure of 20 psi
during fire fighting, line flushing, other unusual conditions.
In the United States the average is approximately 568 liters (125 gallons) per person per day.
The world average is estimated to be approximately 60 liters (16 gallons) per person per day
There will be times during the day when water consumption is much greater than a pumping station averages of water per
minute, such as peak time, morning, and evening
Average daily flow (ADF), Peak hourly flow (PHF) and peak daily flow (PDF)
a) 2.4 for peaking from average daily flow (ADF) to PDF
b) 1.25 for peaking from PDF to PHF
*** Based on the local urban water plan
Pump (kw), Residential, Water supply height and Water flow
Pump KW, Residential, Water supply height and Water flow
Pump Qty*** Pump(kw) Pump(Hp) Height (F) Flow (gpm) Household***
5.5 7.37 246 53 240
5.5 7.37 131 106 480
7.5 10.05 197 106 480
7.5 10.05 157 141 640
7.5 10.05 131 159 720
15 20.1 262 159 720
15 20.1 197 220 1000
***
Pump Qty depends on the household and others demand of the urban water supply
Household: 3 persons per household